Aqua-pure AP-RO5500 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Filtry do wody Aqua-pure AP-RO5500. Performance Data - Aqua Pure Water Conditioning Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 4
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Performance Data Sheet
Model: APRO5500
Reverse Osmosis / Activated Carbon Drinking Water Appliance
System tested and certifi ed by NSF International against NSF/ANSI Standard 58 for the reduction of substances
listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system as specifi ed in NSF/ANSI Standard 58.
Contaminant Reduction Determined by NSF testing.
Contaminant Reduction Average
Infl uent
NSF specifi ed Challenge Concentration Avg %
Reduction
Average Product
Water Concentration
Max Permissible Product
Water Concentration
NSF Reduction
Requirements
NSF Test
Report
Arsenic 0.31 mg/L 0.30 mg/L ± 10% 99.6% 0.001 mg/L 0.010 mg/L N/A J-00058998
Barium 9.7 mg/L 10 mg/L ± 10% 99.4% 0.054 mg/L 2.00 mg/L N/A J-00058995
Cadmium 0.030 mg/L 0.03 mg/L ± 10% 99.2% 0.0002 mg/L 0.005 mg/L N/A J-00058996
Chromium (Hexavalent) 0.29 mg/L 0.3 mg/L ± 10% (added as hexavalent) 99.5% 0.001 mg/L 0.1 mg/L N/A J-00058994
Chromium (Trivalent) 0.31 mg/L 0.3 mg/L ± 10% (added as triavalent) 99.6% 0.001 mg/L 0.1 mg/L N/A J-00058995
Copper 2.9 mg/L 3.0 mg/L ± 10% 99.4% 0.01 mg/L 1.3 mg/L N/A J-00058999
Cyst 187,000 cysts/L Minimum 50,000 cysts/L 99.99% 6 cyst/L N/A ≥99.95% J-00058998
Fluoride 9.1 mg/L 8.0 mg/L ± 10% 98.0% 0.18 mg/L 1.5 mg/L N/A J-00058997
Lead 0.15 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.01 mg/L N/A J-00058996
Radium 226/228 25 pCi/L 25 pCi/L ± 10% 80.0% 5 pCi/L 5 pCi/L N/A J-00058995
Selenium 0.1 mg/L 0.10 mg/L ± 10% (added as ½ selenite and ½ selenate) 98.0% 0.002 mg/L 0.05 mg/L N/A J-00058997
Turbidity 117 NTU 11 ± 1 NTU 99.9% 0.11 NTU 0.5 NTU N/A J-00058998
TDS 740 mg/L 750 mg/L ± 40 mg/L (added as sodium chloride) 94.1 43 mg/L N/A ≥75% J-00034261
Note: While the testing was performed under standard laboratory conditions, actual performance may vary.
Application Guidelines/Water Supply Parameters
Membrane Type TFCM Water Supply Parameters
Water Supply, chlorinated or non-chlorinated
Component Limit
Hardness <350 mg/L
Water Pressure
30-125 psi
(207 -862 kPA)
Iron <0.1 mg/L
Water Temperature
(Cold Water use only)
40º F - 100º F
(4.4º C - 38º C)
Manganese <0.05 mg/L
pH Range 4.0 – 11.0 Hydrogen Sulfi de 0
Maximum TDS level 2000 Turbidity <1 NTU
System Production: 11 gal/day (41.6 L/day)
Post Filter Chlorine Taste and Odor capacity: 2,500 gallons (9,463 liters)
System Effi ciency: 13.2% Effi ciency rating means the percentage of the infl uent water to the system that is
available to the user as reverse osmosis treated water under operating conditions that approximate typical daily
usage.
This system shall only be used for arsenic reduction on chlorinated water supplies containing detectable
residual free chlorine at the system inlet.
Warning: To reduce the risk associated with the ingestion of contaminants: Do not use with water that
is microbiologically unsafe or unknown quality without adequate disinfection may be used on disinfected
waters that may contain fi lterable cysts. EPA Establishment No. 70595-CT-001
CAUTION: To reduce the risk associated with property damage due to water leakage: Read and follow all
instructions before installation and use of this system
Przeglądanie stron 0
1 2 3 4

Podsumowanie treści

Strona 1 - Performance Data Sheet

Performance Data SheetModel: APRO5500Reverse Osmosis / Activated Carbon Drinking Water ApplianceSystem tested and certifi ed by NSF International again

Strona 2

ComponentsSediment Prefi lter: 5 Micron Depth/Activated CarbonMembrane Type: Thin Film Composite (TFCM) Carbon Postfi lter: Activated CarbonTank

Strona 3 - 181506

State of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: August 17, 2006Tr ademark/Model DesignationReplace

Strona 4

Systems must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines. Failure to follow installation, operat

Komentarze do niniejszej Instrukcji

Brak uwag